![rslinx classic ethernet ip rslinx classic ethernet ip](https://www.manualsdir.com/manuals/577370/36/rockwell-automation-842e-ethernet_ip-absolute-encoder-user-manual-page36.png)
#RSLINX CLASSIC ETHERNET IP INSTALL#
You can install version 19 along side of the existing version 17. And maybe I will have to update its mainprogramm too? What the cosequences may follow? Where to read about different revisions compatibility? Because if I update the programm on laptop from 17 to 19 revision I am not sure that I will be able to work with our old line with 17. Maybe our contractor who assembled the line left it to us.Ģ.
#RSLINX CLASSIC ETHERNET IP HOW TO#
How to make sure do I have a Licensed Software (RSLogix5000) on my laptop or crack vesion without risks to lose programm?īecause we have the same PLC on another production line which has version 17.Īnd because we have this programm only in one laptope (RSLogix enterprise) and nobody knows where did we get this laptop. So it will be helpfull if you give me few more answers or links where I could find detailed answers.ġ. And when I have tried upload RSLogix showed an error about different revisions.Įnglish is not my native language and it's hard to find now how to use google in this questions. I was not able to upload programm because RSLogix 5000 on laptop has 17. Thanks again=)īut I've met a next problem. I do not familiar with principles of networking so I did not know that it was impossible to connect with difference masks. Actually laptop couldn't find it because it had IP adress like 192.168 etc. Make sure the ethernet port on your PC is configured for the same subnet as the plc ethernet card. If the processor is v21 you'll have to have RSLinx 3.6 Also your version of logix5000 must match the processor firmware.
![rslinx classic ethernet ip rslinx classic ethernet ip](https://theautomationblog.com/wp-content/uploads/2019/11/TheAutomationShow-EP025-Fi-1.jpg)
Make sure you're using rslinx classic 2.8 or better. In Logix5000 go to the comm tab, open the driver, drill down to the cpu, and select "Upload"
![rslinx classic ethernet ip rslinx classic ethernet ip](https://images.squarespace-cdn.com/content/v1/5ee0cb9d57e1e52bdc8fe76e/1609519499927-3TEGFXEJA2LN1QMQQ1LM/ethernetipdriver.png)
Clicking on it should show the back-plane and further down the cpu. There should be a "+" box beside the Ethernet card. You can right-click on the Ethernet card and be able to bring up a configuration to change the IP address if needed. The card should show up as the ENBT, ENT2, etc. You can use a crossover cable if the Ethernet card isn't on a network switch. Once the driver is running you should be able to "browse" the network under the Ethernet/IP driver using "RSWho". You can select which of your Ethernet ports on your pc to use if needed. There isn't any configuration for the driver on the plc side. Your driver in RSLinx Classic should be the Ethernet/IP not the Ethernet devices. I'm guessing your Ethernet card is a 1756-ENBT or ENT2.